HPLC System (Waters 2695 LC) consisting of quaternary gradient pu

HPLC System (Waters 2695 LC) consisting of quaternary gradient pump,

auto sampler, column oven and PDA detector (2996) was employed for analysis. The output of signal was monitored and integrated using waters Empower software. Chromatographic analysis was performed on Symmetry Hypersil C18 (150 × 4.6 mm, 5 μm) column. Separation was achieved using a mobile phase consist of phosphate buffer with pH 4 and Acetonitrile in the ratio of 82:18 v/v solution at a flow rate of 1 ml/min and run time was 8 min. The eluant was monitored using UV detector at a wavelength 290 nm. The column was maintained at ambient temperature and injection volume of 20 μl was used. The mobile phase was filtered through 0.45 μm filter prior to use. 10 mg of Metronidazole and 10 mg of Norfloxacin were weighed separately and transferred into a 10 ml volumetric flask. The compounds are then dissolved separately in mobile phase and the solutions were filtered Gefitinib mouse through 0.45 μ filter and sonicated for 5 min. Further pipette 1.25 ml of Metronidazole and 1 ml of Norfloxacin into a 10 ml volumetric flask and dilute up to the mark with mobile phase to give final concentration 125 μg/ml of Metronidazole and 100 μg/ml of Norfloxacin. Average

weight of 20 capsules was transferred into a dry 100 ml volumetric flask diluted up to mark with mobile phase. The solution was filtered through 0.45 μ filter and sonicated for 5 min. Then 6 ml of sample stock solution is taken Mephenoxalone in a 10 ml volumetric flask and diluted KU-55933 mw with mobile phase up to the mark (125 μg/ml of Metronidazole and 100 μg/ml of Norfloxacin). The developed method was validated with respect to various parameters such as linearity, accuracy, precision, and robustness, ruggedness, Limit of detection and Limit of quantification as per the ICH guidelines. The results of the validation parameters were shown in Table 1. The

system suitability was assessed by three replicate analyses of the drugs at concentrations of 125 μg/ml of Metronidazole and 100 μg/ml of Norfloxacin. The % RSD of peak area and retention time for the both drugs Metronidazole and Norfloxacin are within 2% indicating the suitability of the system (Table 2). The specificity of the method is performed by separate injections of the Metronidazole, Norfloxacin and sample. The specificity chromatogram was shown in Fig. 3, where the retention time of Metronidazole does not interfere with the retention time of the Norfloxacin. Several aliquots of standard solutions of Metronidazole and Norfloxacin was taken in different 10 ml volumetric flasks and diluted up to the mark with mobile phase such that the final concentration of 75, 100, 125, 150, 175 μg/ml of Metronidazole and 60, 80, 100, 120, 140 μg/ml of Norfloxacin. Calibration curves were constructed by plotting average peak area against concentration (Fig. 4). The LOD and LOQ of the developed method were determined by injecting progressively low concentration of the standard solutions.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>